Our Products

Rotary Evaporator

Laboratory equipment

Jacketed Reactor

Contact Us

We Cherish All Interactions

Antibodies & Protein Biology - Fisher Scientific

The Corning LSE Digital Water Bath is a personal-sized bath with seamless chamber that can accommodate up to 6L of water or can serve as dry bath when using thermal beads. Pricing & .

Food Processing Chiller Cooling Systems: Glycol, Water .

Other chiller companies struggle with water temperatures below 40°F, due to ice forming in the evaporator. In either case, Drake has the system that solves the ice issues and produces a reliable product faster and more economically. Drake routinely designs custom food processing chiller systems to meet the specific needs of your operation .

General Purpose Water Baths - PolyScience

WARNING: The Water Bath's power cord must be connected to a properly grounded electrical receptacle. Make certain that this electrical outlet is the same voltage and frequency as your Water Bath. The correct voltage and frequency of your Water Bath are indicated on the identification label on the rear of .

Steam Driven Vapour Absorption Chiller - Thermax

Unlike electrical chillers, Absorption Chillers are powered by heat. These machines can run on a variety of heat sources, e.g. steam, hot water, liquid/gaseous fuels, exhaust gases and/or a combination of above. Cooling & Heating Division - Cooling SBU To be a globally respected high performance

Water Bath Vapor Glycol - 50% Glycol - ChemWorld

Water Bath Vapor Glycol systems often require 50% solutions of Propylene Glycol with a corrosion inhibitor. ChemWorld stocks Water Bath Vapor Glycol in Salt Lake City, Utah and Atlanta, Georgia. Order online and save today.

How to use a Rotary Evaporator

Most labs use a simple water aspirator vacuum on their rotavaps, so a rotavap cannot be used for air and water-sensitive materials unless special precautions are taken i.e. additional traps are used. In the lab, the house vacuum line, a circulation bath or a membrane pump .

Water Baths - Brookfield

Learn in details about Brookfield's different verity of Water Baths control .

Chapter 14: Chiller Evaluation Protocol

A chiller plant encompasses a chiller—or multiple chillers—and associated auxiliary equipment. This protocol primarily covers electric-driven chillers and chiller plants. It does not include thermal energy storage and absorption chillers fired by natural gas or steam, although a similar methodology may be applicable to these chilled water .

1.3H: Water, Sand, and Oil Baths - Chemistry LibreTexts

Aug 18, 2019 · Contributor; Water, sand, and oil baths are related heat sources as they envelop a flask in a warm material (liquid or sand). A thermometer is often used to monitor the temperature of the bath, and is used to approximate the internal temperature of liquid in a flask (the bath is often slightly hotter than the liquid in the flask).. Water baths, heated on a hotplate, are most commonly used to .

Rotavapor® R-100 | buchi.com

< 10 °C cooling temperature; There are many advantages of heating the bath to a maximum of 50 °C: No risk of scalding when handling the evaporation flask; Lower evaporation of heating liquid (e.g. water) Higher energy efficiency compared to other heating bath temperatures

Basic Concepts of Steam | Tuttnauer

Let's review. We learned that water has three states: ice is the solid state, water vapor is the gaseous state, and water is the liquid state. When water is heated it evaporates, which means it turns into water vapor and expands. At 100℃ it boils, thus rapidly evaporating. And at boiling point, the invisible gas of steam is created.

Ultra Cool Recirculating Chillers | Low Temperature .

The Ultra Cool Recirculating Chillers have a temperature range of -40 to +130C (range varies by model) and a cooling capacity of up to 24000 watts (81910 BTU/hr). Systems are available with centrifugal or turbine type pumps. The rugged design is focused on providing users with 24 x 7 continual operations of these chillers.

Cooling Tower Pumping and Piping

TECHNICAL RESOURCES. J122 QUESTIONS? CALL 410.799.6200 OR VISIT WWW.BALTIMOREAIRCOIL.COM. Cooling Tower Pumping and Piping. Downcomer Siphon Draw. In . Figure 3, water is being discharged at E. Pressure at D must be equal to exit loss plus flow-friction loss DE and minus the static pressure reduction caused by downcomer return static height H. r.

Rotavapor® R-300 | buchi.com

Comfortable flask and vapor duct removal thanks to easy to use Combi-Clip; . When using distilled water, 0.5 g of Borax should be added. Distilled water without any additionally added ions will corrode the bath. . Both bath and chiller enter a stand-by more after a pre-defined period of time and are restarted automatically when required.

Water Bath Chillers | Products & Suppliers | Engineering360

The vapor pressure of iodine in the discharge tube was con- trolled by cooling the bottom end of the tube either in a cir- culating water bath chiller or a dry ice– acetone slurry. Multi-day test of the caustic-side solvent extraction flowsheet for cesium removal from a simulated SRS tank waste.

Cook/Chill Systems | Alabama Power

Tumbler Chillers Tumble chillers are specifically designed to cool filled casings rapidly from 180°F to below 40°F in less than 60 minutes using ice water. The tumbling action is very gentle to avoid casing damage. Food casings are loaded through the entry chute either by hand or by a casing conveyer.

Heidolph Instruments : Rotary Evaporators

Developed with users . In close cooperation with users, we developed the Hei-VAP series of rotary evaporators with an emphasis on the essentials: well thought-out details with a focus on features and functions to facilitate everyday laboratory work.

Water Baths | Thermo Fisher Scientific - US

Water Baths, Circulators & Chillers . Monitor the temperature of your water bath with our nonhazardous spirit-filled glass thermometers. Water Bath Racks. Firmly secure test tubes in water baths with our racks, inserts and trays. Water Bath Cables and Sensors.

Rotary Evaporator Ethanol Extraction - Coldfinger .

Oct 11, 2019 · The water bath is deployed at 30-40 degrees with an ethanol vapor temperature 15-20 degrees C. Lower water bath temperatures prevent thermal decomposition. Increasing the evaporation rate by lowering the vacuum and/or increasing the water bath temperature can lead to capacity overload on the condenser. (Julabo)

Rotavapor R-210 / R-215 Technical data sheet

Rotavapor® R-210 / R-215 Technical data sheet The evaporation of solvents is a routine process widely performed in the laboratory. It is there-fore important that the instruments optimally support the user's working methods and match

Small Water Chiller:

Small Water Chiller Top Selected Products and Reviews IceProbe Thermoelectric Aquarium Chiller - 4 in. x 4 3/4 in. x 7 1/2 in.

Chiller Water Treatments – the Why and How of Closed Loop .

Chiller water treatments should be a must for most chiller plants. where the pipes are made up low carbon steel and normal water is used as the make-up water. Statistics say that for a 1,000 ton chiller, a whopping 15,000 (approx.) saving on the energy bill is possible by opting for an appropriate water treatment program.

(PDF) water chiller - ResearchGate

A 'read' is counted each time someone views a publication summary (such as the title, abstract, and list of authors), clicks on a figure, or views or downloads the full-text.

Applications Engineering Manual - Trane

Chiller There are a variety of water chiller types. Most commonly, they are absorption, centrifugal, helical rotary, and scroll. Some reciprocating chillers are also available. Chillers can be either air- or water-cooled. Major vapor-compression chiller components include an evaporator, compressor(s), condenser, and expansion device(s) (Figure 1).

Chillers - Food Processing | Paul Mueller Company

At Paul Mueller Company we have more than 5 decades of cooling expertise in designing, engineering and manufacturing chillers for your refrigeration applications. We understand every food processing application is unique and has different demands, that's why we work to understand your process and bring you the right chilling solution for your .

Rotavapor® R-100 | buchi.com

< 10 °C cooling temperature; There are many advantages of heating the bath to a maximum of 50 °C: No risk of scalding when handling the evaporation flask; Lower evaporation of heating liquid (e.g. water) Higher energy efficiency compared to other heating bath temperatures

Huber Chiller at Thomas Scientific

The compact Minichillers are an economic and environmentally friendly cooling solution for many laboratory applications. A calculation of water and waste water costs shows that a Minichiller can save up to 48,000 litres of water in a working week and due to its low procurement price, return on.

Kurt J. Lesker Company | Traps & Filters Technical Notes .

When pumping a chamber from atmosphere, between ~10-3 to ~10-8 Torr, the major residual gas component is water vapor. A Meissner trap is, essentially, a coil of tubing through which a liquid/gas cryogen flows to maintain a low surface temperature. Given a low enough surface temperature, it is an efficient pump for water vapor.

Lauda WKL 230 Circulation Chiller Digital Water Bath 6 .

Lauda WKL 230 Circulation Chiller Digital Water Bath 6 Liter Air Cooled Used - unit is in good condition, has some slight visual cosmetic wear from normal use, please see photos for details. Includes everything pictured. Unit will be tested before shipping. Circulation chiller 1-line LED display for display of actual or set temperature User-friendly menu guidance with simplest 3-key operation .

Standard Operating Procedure - Rotary Evaporator

13. Turn on the hot bath using the switch located on the right side of the bath towards the back. Use the dial on the hot bath control panel to set the temperature of the hot bath. Since water is typically present in the hot bath, the heating system will not heat above 100 degrees. 14.